ReadyPlanet.com


office automation product
industrial automation products
Promotion


CEM PORTABLE
PORTABLE GAS ANALYZER

SO2 Infrared Gas Monitor

SOA-7000

                                                

Main Specifications
Method : SO2 : Single light source, dual beam non-dispersive infrared absorption (ratio photometry)
  O2 : Zirconia
Measuring Range : SO2 : 0-100 ppm to 0-1 vol% O2 : 0-5/10/25 vol%
Repeatability : Within ±0.5% of full scale
Zero Drift : SO2 : Within ±1.0% of full scale/day or ±1.5ppm/day,whichever is greater
  O2 : Within ±1.0% of full scale/day
Span Drift : Within ±1.0% of full scale/day
Linearity : Within ±1.0% of full scale
Sample Gas Flow : Approx. 2.0 L/min
Output Signal : 3 Channels (max)
Data Storage : Possible by IC memory card (option)
Power supply : 100 to 240 VAC(50/60 Hz)
Dimensions/Weight: Approx. 323x430x270 mm/14.5 Kg

 

CO/CO2/CH4 Infrared Gas Monitor

CGT-7000

 

 

 

 

 

 

 

Main Specification
Method : CO,CO2,CH4 : Single light source, dual beam non-dispersive infrared absorption (ratio photometry)
  O2 : Zirconia (option)
Measuring Range :
Type 1A Type 1B Type 2 Type 3
0-1000/5000 ppm 0-5/15 vol% CO See Note1,2 for See Note 1 for
CO 0-5/15 vol% CO2 combinations of range combinations
0-5/15 vol%CO2   components and 0-5/10/25 vol% O2
0-5/10/25 vol% O2   ranges  
    0-5/10/25 vol% O2  
Note 1 : The following measurement ranges are prepared for the optional use in condition od max. four ranges for each & max.
sensitivity min. Sensitivity=10:1 Depending on the range area, the sensitivity ratio may be limited to less than 10:1,
CO : 0-100 ppm to 0-100 vol%, CO2 : 0-100 vol% CH4 : 0-200ppm to 0-100 vol%
Note 2 : The maximum difference in concentration between CO and CO2 and between CH4 and CO2 is 1:1500. The maximum difference in concentration between CO and CH4 is 1:20
Repeatability : Within ±0.5% of full scale
Zero Drift : Within ±1.0% of full scale/day
Span Drift : Within ±1.0% of full scale/day
Linearity : Within ±2% of full scale
Sample Gas Flow : Approx. 2.5 L/min
Output Signal : 3 channels(max)
Data Storage : Possible by IC memory card (option)
Power supply : 100 to 240 VAC (50/60 Hz)
Dimensions/Weight: Approx. 323 x 430 x 270 mm/15 K






NOx-O2 Chemiluminescence Gas monitor

 NOA-7000

 

Main Specifications
Method : NOx(NO+NO2) : Atomspheric pressure chemiluminescence
  O2 : Zirconia(option)
Measuring Range : NOx : 0-25/50/100/250/500/1000/2500/4000 ppm
  O2 : 0-5/10/25 vol%
Noise : Within ±1% of full scale
Repeatability :  Within ±0.5% of full scale
Zero Drift : Within ±1.0% of full scale/day or ±1.5% with 25ppm NOx range
Span Drift : Within ±1.5% of full scale/day
Linearity : Within ±2% of full scale
Sample Gas Flow : Approx.2.0 L/min
Air flow to Ozonizer : 1.75 L/min
Convertor Efficiency : 95% or greater at 300ppm No2 or less
Output Signal : 3 Channels(max)
Data Storage : Possible by IC memory card (option)
Power supply : 100 to 240 VAC(50/60 Hz)
Dimensions/Weight : Approx.323 x430x270 mm/15 Kg
   
   

 




SHIMADZU

CEM
CEM ONLINE
TOC On Line
TOC Lab